6860 South Abbott Rd, Orchard Park, NY 14127 -- Phone 716.649.7490 -- Toll Free 888.214.3655

Boston Valley Terra Cotta

Home TerraClad™ Rain Screen Product Testing

Product Testing

E-mail Print PDF

Rigorous testing is conducted on TerraClad™ rain screen assemblies to meet various standards and to ensure the highest quality product.

ASTM C99

Standard Test Method for Modules of Rupture of Dimensional Stone

ASTM C126

Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick and Solid Masonry Units

ASTM E 283-04

Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM E 331-00

Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference

ASTM E 330-02

Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.

ASTM C880

Standard Test Method for Flexural Strength of Dimensional Stone

ASTM C1167-03 and ASTM C67

Standard Specification for Clay Roof Tiles (with modifications as required to ASTM C 67 - Standard Test Method for Sampling and Testing Brick and Structural Clay Tiles)

ASTM C1354

Standard Test Method for Strength of Individual Stone Anchorages in Dimension Stone

AAMA 501.1-05

Standard Test Method for Exterior Windows, Curtain Walls, and Doors for Water Penetration Using Dynamic Pressure

AAMA 501.4

Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Inter-story Drifts

AAMA 501.6-01

Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from a Wall System

AAMA 509-09

Voluntary Test and Classification Method for Drained and Back Ventilated Rain Screen Wall Cladding Systems

Florida Building Code - High Velocity Hurricane Zone Testing, Miami-Dade County NOA08-1014.03

TAS 201-94

Impact Test Procedures - Large Missile Impact

TAS 202-94

Criteria for Testing Products Subject to Cyclic Wind Pressure Loading

TAS 203-94

Criteria for Testing Impact & Non Impact Resistant Building Envelope Components Using Uniform Static Air Pressure

ASTM E 1886

Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

ASTM E 1996-06

Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems by Windborn Debris in Hurricanes

TerraClad Testing

Product Testing
Last Updated on Monday, 26 August 2013 14:30  

Login or Register

Create a user account to give yourself access to all our downloads including CAD files.

 •  Create an account